Saturday, February 9, 2013

HCFC 22 Availability in 2013

This year, 2013, may be the last year of good availability of R-22. It almost certainly will be the last year of “inexpensive” R-22. In fact, we have probably already passed the “inexpensive” threshold. I would like to review the available quantities of R-22 to show a little perspective. The base year that is used in determining the percentages of allowable R-22 production in 1999 when 300 million pounds of R-22 was manufactured or imported in the US. That was cut to 100 million pounds by 2011. However, the reduction also coincided with the elimination of R-22 in the manufacture of new equipment beginning in 2010. Truthfully, we did not feel much of a squeeze because the primary purchasers of the refrigerant were no longer buying it. We even had a bit of a glut for a while, actually driving prices down. Then came the panic of January 2012 when all R-22 production ceased and prices jumped significantly almost overnight. This happened because the EPA had not finalized the rule allowing producers to manufacture and/or import HCFCs in the years 2012 – 2014. Basically, manufacturers did not want to risk receiving a big fine for exceeding the limits in a rule that had yet to be published, so they stopped making R-22. To get the R-22 flowing again, the EPA sent producers a letter stating that the EPA would not bring action against them so long as they did not make more than 55% as much in 2012 as they were allowed to make in 2011. So the amount of R-22 was cut to 55 million pounds for 2012. In fact, that rule has still not been finalized. Instead, the EPA has sent another letter to producers effectively limiting the 2013 allocation to 39 million pounds. Some wholesalers are now concerned about the availability of R-22. It is conceivable that some vendors may run out without being able to replenish their supply. The law of supply and demand is kicking in, driving the prices higher. In fact, now R-22 is now generally higher than the many R-22 replacement refrigerants. I still recommend using R-22 in systems designed for R22. However, you might want to start learning about the different replacement refrigerants available in your area as it looks like R-22 will soon be difficult to find, expensive, or both. One caveat: STAY AWAY FROM FLAMMABLE DROP-IN REFRIGERANTS SOLD OVER THE INTERNET! Putting a flammable gas in a system not intended for flammable gasses is extremely dangerous!
To read more about the availability of R-22 in 2013 read the ACHR News article.

Friday, February 1, 2013

Acetylene Cylinder Safety


I am writing on this subject because I saw a report on CNN discussing an explosion in the back of a car set off by energizing the electric trunk latch. It blew off the trunk and mangled the rear end of the car. Fortunately, nobody was hurt, but the possibility of a lethal accident was certainly there. The fireman that is interviewed mentions that there was an acetylene cylinder in the back of the car which leaked, and the trunk latch set it off. The acetylene should not have been there at all. Acetylene cylinders contain liquid acetone that is stabilized in a porous, cement like material. The acetone is there to dissolve the acetylene gas stored in the cylinder. Acetylene gas is unstable above 15 psig, but must be stored at a much higher pressure to store enough for practical use. Dissolving it in the acetone allows the higher pressure without creating a bomb. The cylinder regulator reduces the acetylene pressure to less than 15 psig. The actual pressure depends on the regulator setting. Note that you should NEVER adjust an acetylene regulator to a pressure above 15 psig.

Since acetylene cylinders contain liquid acetone, they should NEVER be laid on their side. They should ALWAYS be transported in the vertical position, securely fastened to the vehicle. Laying an acetylene cylinder on its side can result in the liquid acetone leaking out into the valve and regulator – setting up a very hazardous situation. You also should not have cylinders in the back seat behind you. Not just for the explosion hazard, but also because of the shifting weight in case of an accident. Any heavy objects behind you will crush you in an accident. My wife’s cousin was killed many years ago transporting cylinders in the back of his car. They crushed him in an accident that would otherwise probably not have killed him. That is why working trucks have a metal cage between the driver and the stuff in the back – to save your life in an accident. Basically, what this all means is that THERE IS NO SAFE WAY to carry an acetylene cylinder in your Prius! If you are going to transport torches or cylinders, you need a properly outfitted truck – not your family sedan.

Friday, January 25, 2013

Winter Airflow


Technicians often hear how critical airflow is in the cooling season, but we sometimes forget that it is just as important in heating as well. Just as poor airflow can be a major source of problems in the cooling season, poor airflow in the heating season can cause inefficient operation, high utility cost, and system failures.

Gas and Oil Furnaces
Gas and oil furnaces will operate with a higher than normal temperature rise if the airflow through the furnace is inadequate. While the air leaving the registers will be toasty, this can actually result in less heat being delivered into the house. The limit switch on a furnace with inadequate airflow will typically cycle the burners on and off  - reducing the amount of heat being produced. The cycling causes poorer operating efficiency, increasing the cost of operating the furnace.

Electric Strips
With electric furnaces and strip heaters, poor airflow will eventually result in open fusible links, bad thermal limits, and open heat strips. Like the gas and oil furnaces, the thermal limits may cycle the strips on and off, reducing the amount of heat.

Heat Pumps
Heat pumps with poor indoor airflow will operate at excessive head pressures because the indoor coil is the condenser in the heating cycle. This reduces system capacity by increasing the compression ratio while the compressor is operating.  Eventually, the compressor will cut off on the high pressure switch. Usually, the high pressure switch will need to be manually reset, meaning no compressor heat until the service tech arrives. Systems without a high pressure switch will shut off on the compressor internal overload. Once that happens, the compressor may not come back on for a couple of hours. Either way, the compressor is taking a beating and the system is using more electricity to produce less heat.

So if you run into furnaces that are cycling on the limit, electric strips with open fusible links, or heat pumps with tripped high pressure switches – check out the system airflow. Remember those are all symptoms – not the root cause. Fix the cause of the problem – poor airflow.

Thursday, January 17, 2013

Short Refrigerant Cylnders

Recently Mr. Simmons, one of our air conditioning instructors at Athens Technical College, noted that a new cylinder of refrigerant felt light compared to the others. A quick check with a scale confirmed his suspicion – the “30 lb” cylinder only weighed 22 lbs including the cylinder and outer cardboard packaging. However, it had never been used. The plastic seal was still intact.  It made me wonder if there were other cylinders that we have used and did not catch. We checked a few others, and it seemed that one cylinder was the only “short” cylinder. Obviously, a cylinder that holds 30 lbs of refrigerant should weigh more than 30 lbs. How much more should it weigh? Generally, the whole package including the box should weigh around 36 lbs. The empty DOT 39 cylinder weighs around 5 lbs and the box weighs approximately 1 lb. I don’t know if our experience is unique, or if it is common for refrigerant cylinders to be short, but I will most certainly be checking from now on. I recommend that you weigh your cylinders before opening the seal to make sure you are getting what you are paying for. A great deal on refrigerant is not a great deal if they don’t actually give you the full amount you are paying for. In our case, I called the company that we purchased the refrigerant from and they quickly replaced the cylinder with a full one. I weighed it to make sure.

Friday, January 4, 2013

Where Are You Headed?

Where are you headed? With the new year, many people ponder what their new year’s resolution should be. One suggestion would be to determine a goal, lay out a plan to reach that goal, and then start working towards it. I read that the legendary quarterback Archie Manning encouraged his sons to write down their goals. Peyton Manning writes his on notecards. I don’t know what was on the cards, but having specific goals and working towards them seems to have worked pretty well for the Mannings. Sometimes students get discouraged by the length of many HVACR programs. The simple truth is nobody can make you a successful technician, or anything else for that matter, in a couple of weeks. The only person that can really make you successful is you. So let me ask you, what are you planning for the next couple of years? Time will pass whether or not you work towards a goal. So where will you be in two years – graduating from a program of study and embarking on a new career, or will you be exactly where you are today?

Friday, December 28, 2012


I have a holiday story to tell that involves pushing people’s buttons and the value of knowledge.
Twas the day after Thanksgiving, and all through the store, frenzied elves were all searching for more. Their buggies were loaded in high rising stacks in hopes that their credit card limits weren't maxed. Their children were manic and running around, in hopes that ipods soon would be found. When up on the roof there arose such a clatter, the manager called me to see what was the matter. His nerves all a-jangle, reason passing away, he requested my services to salvage the day.” I am just sitting down to sup with my kin, first thing in the morning I will gladly begin.” “Please come now” he insisted and pleaded, “this is Black Friday, I’ll pay anything needed. “”I have no boards, no relays or switches. I can’t fix it if more parts are needed.” I quoted a price so round and stout that I thought surely he would wait the day out. When to my wondering ears he replied, “agreed – come quickly before customers fly.” I found a reset, red and protruding, I pushed it to see just what the unit was doing. The dead unit sprang into life and I saw on his face, a look of relief at all the sales saved. I checked to make sure it would run through the night, and promised to return to do it up right. I requested my fee for services rendered, when the manager balked and refused to surrender. “You can’t charge ALL THAT for pushing a button!” “Of course not,” I said, “pushing is free. Knowing which button to push demands the full fee!”

There is nothing wrong with charging for what you know. You have an investment in time and money collecting useful knowledge. It is reasonable and appropriate to charge for it. The customer should know up front what they will be paying and what they will be receiving for their payment.

Disclaimer: This is a fictional holiday tale. No buttons were pushed in the making of this story.

Tuesday, December 18, 2012

Furnace Ignition Sequence

One of the best ways to prepare for troubleshooting any piece of equipment is to learn it’s normal operating sequence. If you understand what is supposed to happen and the order in which nit is supposed to occur, you can narrow the probable causes by observing the unit operation. By carefully observing the operation of a gas furnace, you can often narrow the possible causes of trouble to just a few items based on how far into the sequence the furnace gets. Most furnaces today use many similar components. This includes hot surface igniters to light the burners, induced draft fans to pull the combustion gasses through the heat exchanger, and draft proving switches to insure the draft.

The first step is to energize the induced draft fan. This is the little fan on the front of the furnace, not the larger indoor blower. The induced draft fan runs for a minute or so to purge the combustion chamber. The draft safety switch should close after the induced draft blower starts. If it does not, the process stops there – often with the daft blower continuing to run indefinitely. If the draft switch senses a proper draft, it closes and the sequence continues.

Next, the hot surface igniter is energized. If it is working, you will see a bright glow.

After a warm up period of 30 seconds to a minute, the gas valve is energized. The gas should ignite when it flows over the hot surface igniter.

A flame rod must sense the presence of flames within a few seconds or the system will close the gas valve and start the process again. After several aborted attempts, the system will lock out and quit trying to ignite.

After the flames are ignited, the control turns off the hot surface igniter and waits for the furnace to warm up before operating the indoor blower.

When faced with a furnace that does not operate properly, pay attention to how far into the sequence it gets before the process stops. That can help you decide where to start your troubleshooting.