Monday, April 21, 2014

Tracing a Communications Problem

One bad apple don’t spoil the whole bunch girl …
You may know the Jackson Five hit that line comes from.
(The first time I heard it was NOT on an oldies radio station.)  Unfortunately, when it comes to communicating controls, one bad communicating board CAN take down the whole network. If the communicating portion of a board is sufficiently damaged, it can prevent communication to ANY of the components on the communicating network. This is because they are all tied together in parallel. A sufficiently low resistance can pull down all communication signals on the whole bus. We saw this first hand this week in our lab. A system that had been operating correctly started having problems communicating. A lab instructor had put in a problem and the student tried to troubleshoot by swapping wires around, resulting in a dead board. (In my experience, swapping around wires just to see what will happen almost never ends well!) Now, the ENTIRE SYSTEM stopped communicating and the control could not find the furnace, which did not have any problems. When the communicating wires to the condensing unit were disconnected, the thermostat found the furnace and was able to operate it. The bad condensing unit board managed to pull down the entire communication bus. When you have a communicating control system that will not communicate, the first step should always be to check your connections. Make sure they are correct and making good contact. Then, try to isolate different parts of the system by connecting one part of the system at a time to the communication bus and seeing which specific component will not communicate. Unlike standard 24 volt controls, you cannot read a voltage to determine if a board is communicating. Isolating the components and checking them individually usually identifies the component which is causing the problem.

Friday, August 6, 2010

Communicating Control Systems

The standard air conditioning control system uses relay logic or an electronic representation of relay logic. Things are either off or on. The controls work something like a light switch – when the switch is on the light operates, when it is off the light is off. Thermostats are basically switches that are controlled by temperature. The thermostat closes a set of contacts to complete a circuit to a relay coil, the relay coil then closes the relay contacts to complete a circuit to a motor. When the thermostat is satisfied its contacts open, breaking the circuit to the relay coil. The relay opens its contacts, breaking the circuit to the motor. Everything works based on the presence or absence of control voltage. One advantage of this system is that it is easy to understand, and it has been the basis for HVAC/R controls for many years. However, this control system needs a separate control wire for each function. Some split system heat pumps require 12 control wires running between the indoor and outdoor section. Even with twelve wires, the range of control is still somewhat limited.

A communicating control system is more like a computer network. The system components communicate over a serial network. Each part has its own unique electronic signature or address, allowing the controller to recognize all the parts and coordinate their operation. Most residential communicating systems use four wires between all components – two for power and two for communication. It does not matter if the component is a furnace, air handler, air conditioner, heat pump, or zone control – everything uses the same four wire connection. This works because the units respond to commands sent over the communication network, not the presence or absence of control voltage. Commands for different components can be sent over the same network. Further, communication is not just one way. Communication between components allows them to know what the other components are doing and adjust accordingly. For example, Carrier’s Infinity zone control knows what the blower CFM is and what the CFM in each zone is. Better yet, it can report this to the service technician. The system airflow can be ramped up or down to match system capacity. Staged furnaces, air conditioners, and heat pumps give the system the ability to modulate system capacity and airflow as the house load requires, improving efficiency and reducing energy use. Just a few years ago Carrier was the only game in town if you wanted a residential communicating system. Some folks were not paying too much attention because these systems were only offered in high end equipment made by one equipment manufacturer. Today it seems like everyone is offering a communicating system. Equipment manufacturers advertising communicating systems now include Carrier, Bryant, Trane, American Standard, Lennox, York, Rheem, Ruud, Amana, and Goodman. I apologize in advance for leaving anyone off. The point is that communicating controls are booming. Communicating systems used to be proprietary, now there is an open standard called ClimateTalk. The ClimateTalk will encourage the development of equipment that plays nice across different brands. I don’t believe we are at the point of interoperability yet, but that day is coming. Besides the proprietary systems built exclusively for a particular brand, two major control manufacturers are producing communicating systems – Emerson and Johnson Controls. The availability of “standard” components and an open protocol means that smaller manufacturers can use communicating controls, opening the market up even more. In the very near future, every technician will need to work with communicating controls regardless of the brand equipment their company sells and services.

For more details regarding communicating control systems check out Unit 52 Heat Pump Installation, and Unit 59 Zone Control Systems in Fundamentals of HVAC/R. Many manufacturers also have some information online regarding their communicating systems, including