Friday, March 25, 2011

Dry R22 Units

I got my first look at a “dry” unit the other day. A wholesale house had one on its showroom floor with a big sign “we have dry units!” I looked at the nameplate to see what it said about refrigerant. A refrigerant amount was actually listed. Instead of the familiar “factory charge” preceding the refrigerant quantity, it had “Field Charge” and then the amount. I asked about coil matching for older systems. They recommend 1/2 ton smaller condenser than the original for heat pumps and the same size condenser for air conditioning. Then I asked about warranty and they said the units came with a 5 year compressor warranty regardless of the coil connected to it. They pointed out that this was less than the warranty on new matched equipment. Many of the units are being sold to replace condensing units that have been stolen or chopped up in place, often in rental property. Another wholesaler requires you to take coil measurements and then uses software to try and figure out the coil SEER. If the calculated SEER is less than 13, they recommend against buying the dry unit. Companies that just a few years ago were cautioning against the perils of mismatches units are now selling units that will almost certainly be mismatched. They cannot provide any meaningful charging chart without knowing what coil is on the other end of the system.  

If you do decide to install a “dry’ unit, make sure and follow good refrigeration system installation practices. The fact that you are creating your own special blend of equipment makes it all the more important to be careful, not careless. It would be wise to treat the job like a compressor burnout. Flush the lines and coil, install a filter drier, pull a good vacuum, and weigh in the charge using an accurate digital scale. You can see more about line flushing at Mainstream Engineering. They sell a flush designed for this type of use. You will need to adjust the data plate charge for line length and possibly coil mismatch, but the nameplate charge should be in the ballpark unless you have very long lines. I think it might be wise to start a little under, so I would not adjust for line length until after starting the unit.  I found a good set of instructions for installing dry systems online provided by Century, a supplier that is offering dry units. No, these are NOT the folks who suggested the 1/2 under ton heat pump coil adjustment. The link to the guide is:

http://www.centuryac.com/DryChargeInstructionsandchart.pdf

Saturday, March 19, 2011

Spring Fever!

Spring is always a busy time for events and meetings. The state SkillsUSA Championships are going on across the country. I spent the day this past Friday at the Georgia  International Convention Center in Atlanta viewing the competition. Shumate Mechanical provided all the judges for the HVACR competition. I was very impressed by the way they interacted with the students encouraging and teaching them. Kudos to Shumate for going out of their way to help with the SkillsUSA Contest. I was also impressed by the poise and professionalism of all the contestants. It is not easy to work under a microscope with judges and spectators peering at you while you work. They only had 18 minutes to complete each task, adding to the stress level. But despite these pressures, they all held up admirably. Along the way, the students competing learn more than HVACR skills, they learn something about themselves. Taking up the challenge and seeing it through requires a lot of effort above and beyond the normal demands of most HVACR programs. I was very proud of the preparation and hard work Keith Watermann from my program put into the competition and his hard work showed. The winners of the state contests will meet in Kansas City later this summer June 19-24  for the national championships. 


The National HVACR Educators and Trainers Conference starts Sunday, March 20th in Las Vegas. However, if you are not registered already you will miss it because it is sold out. I spoke with Howard Weiss, and he said he hated to keep people out, but they have reached the maximum number of people the fire code will allow in the room! If you are lucky enough to be registered, be sure and say hello to David Skaves, my writing partner on Fundamentals of HVACR. He will be at the Pearson booth and he will be speaking at 9:15 on Monday on Strategies for Connecting with Today’s Student in the Age of Electronics. 


If you missed the Las Vegas show, you can still catch the HVACR & Mechanical Instructor’s Workshop in Landsdowne, Virginia at the National Conference Center. This longest running HVACR Instructor’s workshop was started by ARI and today is supported by an impressive list of industry heavy hitters including AHRI, ACCA, ACTE, CARE, HARDI, HRAI, NAOHSM, NATE, PHCC, RSES, SkillsUSA. It is March 23-25 and there is still room. It is too late to register online, but you can still register at the Conference Center. The Conference is free if you stay at the National Conference Center. There is a $65 per day fee if you are staying elsewhere. Freddie Williams will be there at the Pearson booth. He is the author of the MyHVACLab material. Freddie is the man to talk to if you have questions about using online material in your program. Besides being the author of MyHVACLab, he has extensive experience with both Blackboard and Angel. If you cannot go to anything this year, just remember next January to start planning your strategy for attending one of these events. It does take some planning, but it is worth the effort.  

Friday, March 11, 2011

I-Phone, The HVACR Service Tool of Today

Do you have an I-Phone on your list of required service tools? I can not help but notice the increasing number of students in my classes that regularly use smart phones, I-Pads, and laptops. One student brings in his I-Pad and follows along on MyHVACLAb while I am lecturing. However, creative phone use goes well beyond using MyHVACLab. Students are looking up compressor data, working with PT charts, comparing different gauge sets, and pulling down articles posted on the web. I-Phones, Androids, and  I-Pads are not really phones, they are hand held computers that are always connected to the internet. Oh, and they can be used for phone calls too. So while discussing PT charts, superheat, and subcooling I notice that four or five of my students are looking at their phones rather than the chart I am displaying. Why? They are using the free Bitzer app that puts a PT chart on their I-Phone. When discussing different gauge sets, one student shows me different models he has found, asking about the pros and cons of each. Copeland has just announced that they have released an app that gives a complete reference of their compressor data. Add to that the many smart phone accessible standard web pages with service data and you start to see that a smart phone really becomes a very useful service tool, connecting the technician with more service literature and data than could be carried around in printed form.  More than ever, I see the job of the instructor as teaching our students how to intelligently use this information. Having access to a mountain of information does not make you a technician. You have to sort out the useful form the junk, and you need to know how to apply the information to solve problems. It is more important that students understand how to use this information than it is for them to memorize any particular piece of information. Rather than restrict the use of phones in class, I allow students to use them so long as it is not for texting their girlfriend. Allowing students to use their phones in class can be a little intimidating because you realize that you do not completely control the flow of information. That is OK. I do not see my job as one of stuffing information into my students craniums. That is their job! I try to think of myself not as a walking air conditioning encyclopedia, but as a coach whose job is to get the best out of each member of my team. I need to figure out where the gaps in understanding are and guide each student to improve their understanding of the information. If you allow phone use in class, inevitably someone will be texting their girlfriend rather than looking up compressor data. They are easy to spot. They don’t ask any questions or participate in the general discussion. The HVACR app masters are looking up PT charts for some refrigerant you never heard of before, pummeling you with questions and sucking in information at a breathtaking pace. The next generation of technicians is adapting the tools of their generation to the problems they face today. Smart phones are the service tools of tomorrow today. 

Wednesday, March 2, 2011

Consensus Appliance Agreements Act

In the February issue of the RSES online Journal John Iwanski discusses the current proposals for the Consensus Appliance Agreements Act and new Energy Star standards. These are still proposals, not law, but they could definitely have a major impact on our industry. The most significant thing I see is that efficiency minimums would be different for different sections of the country. An 80% furnace would be legal in Georgia, but not in Maine. Or more interesting, Arizona would have different standards than Colorado or Texas. A number of industry organizations were involved in the negotiations, among them AHRI. The EPA is also proposing changes to the Energy Star program. To read more about the Consensus Appliance Agreement Act or the Energy Star proposal, go to


Positions of Industry Organizations
PRO
       ASE Alliance to Save Energy
       AHRI Air Conditioning Heating and Refrigeration Institute
CON
      HARDI Heating Air Conditioning and Refrigeration Distributors International

Thursday, February 24, 2011

Thermostat Recycling

What do we do with all these old mercury bulb thermostats? Very few contractors still install new mercury bulb thermostats, but they remove them every day. When I asked a local wholesaler a few years ago about thermostat recycling they proudly said “we don’t sell any.” I congratulated them on their eco stewardship and forward thinking and asked, “so what do I do with the mercury bulb thermostats that I take OFF?” One suggestion was to leave them with the customers. That makes it their problem, not mine. However, that probably increases the likelihood that the thermostat will be tossed in the trash. Besides, our customers expect service; that is what we are paid to provide. Service includes more than fixing machines and changing parts. Many thermostats, including digitals, include the little paper admonishing us to “dispose of properly” without giving a clue as to how to do that. That is where the Thermostat Recycling Corporation comes in. TRC is a non-profit corporation voluntarily founded by thermostat manufacturers Honeywell, White-Rodgers and General Electric for the purpose of collecting and properly disposing mercury-containing thermostats. TRC now represents nearly 30 manufacturers that historically distributed mercury-containing thermostats in the US. TRC’s commitment to collect and properly dispose of mercury-containing thermostats reflects its members’ commitment to keep those thermostats out of the solid waste stream. The program is simple. Participating wholesalers receive TRC collection bins. You just put the old mercury bulb thermostats in the collection bin at the wholesaler. The wholesaler sends the thermostats to TRC and TRC sends the wholesaler back an empty bin. TRC then arranges for the mercury in the mercury bulbs to be recycled. The HVAC contractor’s sole responsibility is simply to take the thermostats to a participating wholesaler. The program does not cost the contractor or wholesaler anything; TRC picks up the tab for the cost of the bins and shipping. HARDI, Heating, Air Conditioning, and Refrigeration Distributors International, is a partner in promoting thermostat recycling through TRC (read about it). For more information on the thermostat recycling program, check out the TRC website or ask your local wholesaler about the program. We all have a stake in this. Not just to prevent pollution caused by discarded air conditioning parts, but to promote our industry as a clean industry acting responsibly to take care of our own mess.   

Saturday, February 19, 2011

HVAC/R Language

A little over a year ago I posted an article on acronyms. Today I am expanding on that idea and offering suggestions on how to avoid confusing your students with HVAC/R techno-speak. We have our fair share of acronyms in HVAC/R. Used properly; acronyms speed up communication by reducing long polysyllabic phrases to a few letters. For example, speakers would get a bit winded if they used the phrase “heating, ventilating, air conditioning, and refrigeration” repeatedly in a conversation. The abundance of industry specific acronyms and the use of more than one acronym for the same item can be truly bewildering to students. For example, one major valve manufacturer uses the acronym TEV to represent “Thermostatic Expansion Valve,” while another uses the acronym TXV for the same thing. They do not represent two different types of components, just two different ways to abbreviate the same words.

When introducing a new topic, using acronyms can lead to confusion and misunderstanding. Worse, students can start to pick up the jargon, but use it incorrectly. It can be difficult for teachers who have had years of experience with HVAC/R techno-speak to remember that the acronyms we casually throw around often have no meaning for our students. Imagine listening to a lecture in which every important concept was in Russian! For example: “The evaporator delta T is controlled by the TEV adjustment, the return air wb, and the CFM.” Now I believe that most any air conditioning instructor understands this sentence, but it is essentially unintelligible to many air conditioning students. It might as well be in Russian! Replacing the HVAC/R specific jargon with the wingdings font it looks like “The evaporator delta T is controlled by the TEV adjustment, the return air wb, and the CFM.” THAT is what this sentence looks like to a new student!

In general it is a good idea to resist using an acronym for something until that item or process has been discussed. Otherwise, the acronym will appear to students to be a mysterious grouping of letters used by air conditioning shaman to communicate with each other. The acronyms and jargon become a secret language which they are not familiar with. I believe that acronym free language promotes better understanding.

Of course, students must still learn the HVAC/R language. Having a solid grasp of the terminology is necessary to make use of essential technical literature produced by equipment manufacturers. Once they are understood, acronyms help us communicate. Can you imagine actually writing out or saying positive temperature coefficient thermistor every time we disused PTC devices? However, the acronyms must first be explained and defined before they are used. It is much easier to remember an acronym if you understand what the letters stand for. When using an acronym for the first time make sure and explicitly spell out what the letters represent, this will increase student’s understanding and retention of the term. It also helps for the students to have a good mental picture of the object or process being described. They are far more likely to remember what  Δ T (Delta T) stands for if they have actually measured a temperature difference and you have discussed it in class. That way the abbreviation is not an esoteric piece of jargon attached to something they don’t understand, but a name for something they have done. In Fundamentals of HVAC/R, we always use the complete word or phrase before introducing an acronym. It helps to explain concepts plainly. After introducing the concept, we give the technical terminology that is used to refer to the concept. The students are more likely to remember the terminology if it is logically connected to something they understand.

Fundamentals of HVAC/R has a unique abbreviation and acronym dictionary to help students learn the language of HVAC/R. Students can find out exactly what is meant by a particular acronym or abbreviation in Appendix C which lists the definition of common acronyms and abbreviations used in HVAC/R. The acronym dictionary is very useful when students are reading industry literature and need help with a particular abbreviation or acronym. For definitions of acronyms the students use when texting each other you will have to refer to another reference, acronymfinder.com  


BFN GTG

Thursday, February 10, 2011

HVAC/R Instructor's Conferences Coming in March

Two national instructor’s workshops are coming soon – one on the west coast and one on the east coast. The HVAC Excellence National HVACR Educators and Trainers Conference is this coming week March 20 – 2 at the South Point Hotel in Las Vegas Nevada. The HVACR & Mechanical Instructor’s Workshop is later the same week, March 23 – 25 in Landsdowne Virginia. This workshop is sponsored by a group of eleven industry organizations, including AHRI who initially started this annual workshop over a decade ago. Both conferences have an impressive list of speakers and topics. David Skaves will be speaking at the Las Vegas conference. He is co-author of the new AHRI text Fundamentals of HVAC/R. If you can find a way to attend one of these conferences you won’t be disappointed. They are well worth your time. Unlike generic teacher’s conferences that target all subjects, these are specific to our field. And unlike industry showcases like ComforTech or the AHR show, these are specifically for teachers. As a result, everything you see will have a direct application to teaching HVAC/R.

I know that times are tough and getting funding and permission to go is difficult. When presenting the idea to your school administrators be sure to forward a copy of the program from the conference(s) that you want to attend. Both the National Educators and Trainers Conference in Las Vegas and the HVACR & Mechanical Instructor’s Workshop have well done professional programs on the web (click on the conference name). Be sure to note the large number of educational sessions. There are literally more sessions than you will have time to attend. Point out that attending will keep you informed about emerging technology like communicating systems. Point out that by attending you will be better positioned to integrate green mechanical concepts into your curriculum as a result of attending the conferences.