Thursday, February 24, 2011

Thermostat Recycling

What do we do with all these old mercury bulb thermostats? Very few contractors still install new mercury bulb thermostats, but they remove them every day. When I asked a local wholesaler a few years ago about thermostat recycling they proudly said “we don’t sell any.” I congratulated them on their eco stewardship and forward thinking and asked, “so what do I do with the mercury bulb thermostats that I take OFF?” One suggestion was to leave them with the customers. That makes it their problem, not mine. However, that probably increases the likelihood that the thermostat will be tossed in the trash. Besides, our customers expect service; that is what we are paid to provide. Service includes more than fixing machines and changing parts. Many thermostats, including digitals, include the little paper admonishing us to “dispose of properly” without giving a clue as to how to do that. That is where the Thermostat Recycling Corporation comes in. TRC is a non-profit corporation voluntarily founded by thermostat manufacturers Honeywell, White-Rodgers and General Electric for the purpose of collecting and properly disposing mercury-containing thermostats. TRC now represents nearly 30 manufacturers that historically distributed mercury-containing thermostats in the US. TRC’s commitment to collect and properly dispose of mercury-containing thermostats reflects its members’ commitment to keep those thermostats out of the solid waste stream. The program is simple. Participating wholesalers receive TRC collection bins. You just put the old mercury bulb thermostats in the collection bin at the wholesaler. The wholesaler sends the thermostats to TRC and TRC sends the wholesaler back an empty bin. TRC then arranges for the mercury in the mercury bulbs to be recycled. The HVAC contractor’s sole responsibility is simply to take the thermostats to a participating wholesaler. The program does not cost the contractor or wholesaler anything; TRC picks up the tab for the cost of the bins and shipping. HARDI, Heating, Air Conditioning, and Refrigeration Distributors International, is a partner in promoting thermostat recycling through TRC (read about it). For more information on the thermostat recycling program, check out the TRC website or ask your local wholesaler about the program. We all have a stake in this. Not just to prevent pollution caused by discarded air conditioning parts, but to promote our industry as a clean industry acting responsibly to take care of our own mess.   

Saturday, February 19, 2011

HVAC/R Language

A little over a year ago I posted an article on acronyms. Today I am expanding on that idea and offering suggestions on how to avoid confusing your students with HVAC/R techno-speak. We have our fair share of acronyms in HVAC/R. Used properly; acronyms speed up communication by reducing long polysyllabic phrases to a few letters. For example, speakers would get a bit winded if they used the phrase “heating, ventilating, air conditioning, and refrigeration” repeatedly in a conversation. The abundance of industry specific acronyms and the use of more than one acronym for the same item can be truly bewildering to students. For example, one major valve manufacturer uses the acronym TEV to represent “Thermostatic Expansion Valve,” while another uses the acronym TXV for the same thing. They do not represent two different types of components, just two different ways to abbreviate the same words.

When introducing a new topic, using acronyms can lead to confusion and misunderstanding. Worse, students can start to pick up the jargon, but use it incorrectly. It can be difficult for teachers who have had years of experience with HVAC/R techno-speak to remember that the acronyms we casually throw around often have no meaning for our students. Imagine listening to a lecture in which every important concept was in Russian! For example: “The evaporator delta T is controlled by the TEV adjustment, the return air wb, and the CFM.” Now I believe that most any air conditioning instructor understands this sentence, but it is essentially unintelligible to many air conditioning students. It might as well be in Russian! Replacing the HVAC/R specific jargon with the wingdings font it looks like “The evaporator delta T is controlled by the TEV adjustment, the return air wb, and the CFM.” THAT is what this sentence looks like to a new student!

In general it is a good idea to resist using an acronym for something until that item or process has been discussed. Otherwise, the acronym will appear to students to be a mysterious grouping of letters used by air conditioning shaman to communicate with each other. The acronyms and jargon become a secret language which they are not familiar with. I believe that acronym free language promotes better understanding.

Of course, students must still learn the HVAC/R language. Having a solid grasp of the terminology is necessary to make use of essential technical literature produced by equipment manufacturers. Once they are understood, acronyms help us communicate. Can you imagine actually writing out or saying positive temperature coefficient thermistor every time we disused PTC devices? However, the acronyms must first be explained and defined before they are used. It is much easier to remember an acronym if you understand what the letters stand for. When using an acronym for the first time make sure and explicitly spell out what the letters represent, this will increase student’s understanding and retention of the term. It also helps for the students to have a good mental picture of the object or process being described. They are far more likely to remember what  Δ T (Delta T) stands for if they have actually measured a temperature difference and you have discussed it in class. That way the abbreviation is not an esoteric piece of jargon attached to something they don’t understand, but a name for something they have done. In Fundamentals of HVAC/R, we always use the complete word or phrase before introducing an acronym. It helps to explain concepts plainly. After introducing the concept, we give the technical terminology that is used to refer to the concept. The students are more likely to remember the terminology if it is logically connected to something they understand.

Fundamentals of HVAC/R has a unique abbreviation and acronym dictionary to help students learn the language of HVAC/R. Students can find out exactly what is meant by a particular acronym or abbreviation in Appendix C which lists the definition of common acronyms and abbreviations used in HVAC/R. The acronym dictionary is very useful when students are reading industry literature and need help with a particular abbreviation or acronym. For definitions of acronyms the students use when texting each other you will have to refer to another reference, acronymfinder.com  


BFN GTG

Thursday, February 10, 2011

HVAC/R Instructor's Conferences Coming in March

Two national instructor’s workshops are coming soon – one on the west coast and one on the east coast. The HVAC Excellence National HVACR Educators and Trainers Conference is this coming week March 20 – 2 at the South Point Hotel in Las Vegas Nevada. The HVACR & Mechanical Instructor’s Workshop is later the same week, March 23 – 25 in Landsdowne Virginia. This workshop is sponsored by a group of eleven industry organizations, including AHRI who initially started this annual workshop over a decade ago. Both conferences have an impressive list of speakers and topics. David Skaves will be speaking at the Las Vegas conference. He is co-author of the new AHRI text Fundamentals of HVAC/R. If you can find a way to attend one of these conferences you won’t be disappointed. They are well worth your time. Unlike generic teacher’s conferences that target all subjects, these are specific to our field. And unlike industry showcases like ComforTech or the AHR show, these are specifically for teachers. As a result, everything you see will have a direct application to teaching HVAC/R.

I know that times are tough and getting funding and permission to go is difficult. When presenting the idea to your school administrators be sure to forward a copy of the program from the conference(s) that you want to attend. Both the National Educators and Trainers Conference in Las Vegas and the HVACR & Mechanical Instructor’s Workshop have well done professional programs on the web (click on the conference name). Be sure to note the large number of educational sessions. There are literally more sessions than you will have time to attend. Point out that attending will keep you informed about emerging technology like communicating systems. Point out that by attending you will be better positioned to integrate green mechanical concepts into your curriculum as a result of attending the conferences.

Saturday, February 5, 2011

Interactive Programable Thermostat Simulators

Have you ever found configuring , programming, or setting a digital thermostat somewhat confusing?  While the new digital do-it-all thermostats are really cool, they can be confusing to set up. If you don’t configure them correctly, you may be unpleasantly surprised at the system operation. Of course you need to read the instructions. These are not for shoot first and read later service cowboys. However, you may not want to be reading the instructions for the first time on the job. Open the box and read the instructions before you arrive to install the thermostat. Most will operate on batteries, they do not have to be wired to be configured and set. Put batteries in and become familiar with the thermostat before arriving on the job. If you already know the system type, you can perform most of the configuration before arriving on the job. If you would like to play with a touch screen thermostat but don’t happen to have one handy, you can often find interactive simulations on line. These let you configure and program the thermostat using the exact same touches, only the touches are mouse clicks. Here are a few to get you started
Honeywell Prestige (downloads a file that you must run)
Lux  


To learn more about HVAC/R check out Fundamentals of HVAC/R

Saturday, January 29, 2011

New Age Digital Tools

I am a big fan of tools that make my work easier. Tools that improve your efficiency not only make your life easier, they make sense economically. The most expensive part of a service call is the service tech. Your time is more valuable that most of the parts you put on. I don’t mean what you receive in your paycheck, but what you cost the company. You cost more than the parts. Saving your time saves the company’s money. I know one contractor that understands this. He does not want techs trying to work with worn out or inappropriate tools. He understands that the time they spend trying to work with the wrong tool costs him money. So his company supplies all the tools for his techs and even replaces them when they are worn or lost. Today’s technicians can benefit from a wide array of technology driven new-age HVAC/R tools. Digital everything! Now technicians can use digital tools to measure pressure, temperature, superheat, subcooling, vacuum, relative humidity, dew point, wet bulb temperature, weight, air pressure, barometric pressure,  air speed, CO, CO2,  and combustion efficiency just to name a few. I did not even include all the electrical measurements available with today’s multi-meters. Indeed, there are many tools available that measure several system characteristics. I must admit that when I look through a catalog of a company that carries several lines of these tools I feel like a kid again looking through the toy section of Sears Christmas catalogue checking off every shiny toy. I want this, I want this, …It would be easy to spend $10,000 on inexpensive digital tools. But since that exceeds the weekly take home pay of your typical service tech, we have to make some choices. The parameters I use in deciding are
  1. Does it do something that I need to do often?
  2. Is it really superior and faster than what I do now, or is it just digital?
  3. Can it do something that I can’t do now?

So by all means, arm yourself with an armada of new-age digital tools, but take time to assess what the new tool will do for you before you invest your paycheck. Otherwise, you could end up with a large collection of expensive digital toys.
If you would like to learn more about HVAC/R, check out Fundamentals of HVAC/R.

Monday, January 24, 2011

Poly Who?

The emergence of HFC refrigerants has added a new set of confusing chemical names and properties with which the HVAC/R technicians must be familiar. One of the more confusing developments in the refrigeration industry in recent years has been the plethora of impossibly difficult to pronounce polys used for refrigerant oil with the new HFC refrigerants. There are several synthetic lubricants with multisyllabic names that begin with poly: polyalkylene glycol, polyol ester, and polyvinylether. Polyol ester is actually “short” for neopentyl polyol ester. To make discussion of these chemicals possible, they are generally referred to by three letter abbreviations:  PAG, POE, and PVE. Polyalkylene glycol(PAG) is widely used in car air conditioning systems, but is generally not used in hermetic and semi-hermetic systems because of its lower electrical resistance. Currently, polyol ester, POE, is the primary lubricant in hermetic and semi-hermetic systems using HFC refrigerants. POE has been used for years as a lubricant in jet engines. One advantage POE has in refrigeration is that it is compatible with a wide range of refrigerants including CFCs, HCFCs, and HFCs.  Another important characteristic is relatively high electrical resistance, making POE superior to PAG for hermetic and semi-hermetic systems. A major disadvantage is that POE is very hygroscopic; it readily absorbs water. Water is never welcome in a refrigeration system (unless the system is a lithium bromide chiller). However, water in a system with POE is a particularly bad set of circumstances. To understand why this is such a problem you need to understand how POE is made. POE is made by a reaction with acid and alcohol which yields water and POE. Like many chemical reactions, it can be reversed. Add water and heat, and POE reverts to acid and alcohol. The hydrolysis of POE creates goo that clogs metering devices, filters, screens, and oil holes. Filter driers are absolutely essential for all systems with POE because of this added water hazard. Even deep evacuation will not adequately dehydrate a POE system if there is already any water in the POE. Some links to sites that discuss these lubricants are PAG, POE, and PVE.    

Thursday, January 13, 2011

Hero Convoy

I was in Nashville this past weekend nervously watching the weather reports and trying to determine exactly when I needed to start my six hour trip back home in order to beat the impending winter storm. There was heavy traffic all the way, all manner of cars, trucks, and commercial vehicles. Maybe they were also trying to beat the storm south. Mixed in with the regular traffic were several convoys of cherry pickers from several states. There was a convoy of 30 bucket trucks from a power company in Michigan. I also remember another convoy of trucks from Kentucky. A lot of my pent up concern and worry melted away when I saw these convoys of heroes because I knew good people were positioning themselves to help. While the rest of us were trying to run away from the storm, they were running towards it. What does a hero look like? If you are cold and out of power, the guy in the bucket truck is way better than superman. A hero is someone who leaves the comfort of home and travels to places where the weather is guaranteed to be wretched so they can hang from a pole and play with wires that could have thousands of volts traveling through them. Heroes aren’t super human beings that accomplish awesome tasks easily without effort or suffering. No, heroes are everyday folk who put forth the effort and bear the suffering for the sake of the rest of us. Thank God for the heroes in the bucket trucks!